text.skipToContent text.skipToNavigation

Power Supply for the AMX 4 LVLE

2366118
2318476 46-302350P1 46-302350P2 46-302350P3
X-Ray
Definium AMX700
GE Sistemas Médicos de México S.A. de C.V
GE HealthCare
Añadir a la lista de deseos
Iniciar sesión y agregar al carrito
Iniciar sesión y agregar al carrito
Please select date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


El artículo no está disponible en inventario con las cantidades seleccionadas. Por favor actualice la cantidad para continuar.

Características

  • Supply is not affected by changing temperature and humidity conditions
  • Reliable source
  • The power supply complies to all regulations like CISPR 11/EN 55011(limits and methods of measurement for ISM equipment), CISPR 22/EN 55022 (limits and methods of measurements of radio interference of IT equipment) CSA 22.2 No. 601.1 (medical electrical equipment, Part 1 general requirements for safety)
  • It complies with IEC 60601-1 (601-1), IEC 60601-1-2 (electromagnetic compatibility), UL 1950 (safety of IT equipment), IEC 60950 and underwriters laboratories standard UL 2061, X-ray equipment

Descripción del producto

The Power Supply is used in many Radiographic systems, which are used to for imaging method diagnosis using X-rays. The systems work on the principle where high velocity electrons, when interacted with patient’s body, their kinetic energy is converted into electromagnetic radiation (X-rays). A detector that is in line with the source of rays, detects them and measures their properties. The AMX 4 is a portable X-ray machine where Low Voltage Low Energy (LVLE) power is supplied to the machine and 4 outputs are provided. A power fail detect signal is also provided. The output voltages do not overshoot at turn-on or turn-off. Several tests like output voltage accuracy, power fail detection/low input power detect test, line regulation (to calculate the effect of input variation on output voltage), load regulation test (to illustrate the change in output voltage resulting from a change in the load), efficiency test (the ratio of output power to input power), P/P ripple test (to illustrate the magnitude of voltage variation on the outputs), Hi-Pot test (to measure the amount of insulation present between the input terminals and metal enclosure), peak inrush current, turn on delay test, overshoot, overload protection & output stability over time test are performed on the power supply before it is used in real time operation.

Artículo equivalente:

Tenemos las siguientes piezas equivalentes disponibles para usted. Estas son piezas de reemplazo compatibles. Estas piezas sin un hipervínculo se enumeran solo como referencia y no están disponibles para su compra en línea. Para obtener información adicional, comuníquese con el servicio al cliente

Artículo equivalenteDetalles de parte
2318476 POWER SUPPLY FOR THE AMX 4, LVLE
46-302350P1 This is a specially designed Low Voltage, Low Energy (LVLE)
46-302350P2

This is a specially designed Low Voltage, Low Energy (LVL

46-302350P3

This is a specially designed Low Voltage, Low Energy (LVL