46-281256P1
Magnetic Resonance Imaging
1.5T Signa Explorer
GE Sistemas Médicos de México S.A. de C.V
GE HealthCare
Añadir a la lista de deseos
Iniciar sesión y agregar al carrito
Iniciar sesión y agregar al carrito
Please select date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


El artículo no está disponible en inventario con las cantidades seleccionadas. Por favor actualice la cantidad para continuar.

Características

  • Superior strength
  • High corrosion resistance
  • Excellent machinability
  • High hardness

Descripción del producto

The Contact Band is used in the magnet ramping equipment of MRI systems. It is fit for the parts that must retain their shape under repeated stress and strain. The band is made up beryllium copper, which is a copper alloy with 0.5% - 3.0% beryllium and other elements. Beryllium copper combines high strength with non-magnetic and non-sparking qualities. It is an extremely versatile material suitable for various operations. It can effectively transmit heat and electricity and it maintains its strength even at very low temperatures. This unique composition of material offers excellent machinability, it can be machined when it is soft and then retain its shape after being heat-treated to the desired hardness. Due to its excellent properties this contact band is used in many MRI systems such as MR Signa HD Excite 1.5T, MR Signa Advantage 0.5T, MR Signa Horizon Hi speed LX 1.5T, HCS-IT AW Workstation 3.1, MR Signa Excite 1.5T, MR Signa Voyager 1.5T, MR Signa Advantage 1.5T and MR Max Plus 0.

  • Características adicionales

    • Good electrical and thermal conductivity
    • Non-magnetic
    • Non-sparkling
    • Good oxidation resistance